Inverter Sizing
Recommend inverter AC rating from PV DC and DC/AC ratio.
ElectricalCore inputs only — quick sizing with engineering defaults.
Inputs (SI units)
Results
Save & Load Project
Designs are stored privately in this browser — nothing is uploaded.
Engineering Formula
- P_ac = P_dc / (DC/AC)
- S_ac = P_ac / PF [kVA]
- Oversizing % = (DC/AC − 1) × 100
Inverters are typically DC-oversized to clip infrequent peaks and lift CUF. 1.10–1.30 is standard for India / IEC climates.
Step-by-step Calculation
- 1.AC
Pdc/(DC/AC)8.33 kW - 2.kVA
Pac/PF8.33 kVA
Design Assumptions
- • Losses in DC combiners < 2%.
- • Ambient inverter derating negligible up to 45 °C.
Engineering Tips
- ◆Pick the next standard AC rating up (5, 10, 15, 25, 40, 50 kW).
- ◆Balance strings equally across MPPTs.
Warnings
- ▲DC/AC > 1.35 risks clipping > 3% and voids some warranties.
Standards & References
IEC 62109-1/2IEEE 1547CEA Technical Standards (India)