Pipe Size Calculator

Choose the right pipe diameter for a given water flow so the velocity stays safe and pressure loss is low.

EngineeringInstant resultsFormula shown100% in your browser

Inputs

1.0–2.0 m/s for water pipes

Formula

  • Area = flow ÷ velocity
  • Diameter = √(4 × area ÷ π)
  • Head loss ≈ 10.67 × L × Q^1.85 ÷ (C^1.85 × D^4.87)

Water pipes are sized by velocity. Too slow and the pipe is oversized and expensive; too fast (above about 2.5 m/s) and you get noise, water hammer and heavy pressure loss. Divide the flow by the target velocity to get the required area, then convert to a diameter and round up to the nearest standard pipe.

Step-by-step calculation

  1. 1

    Area

    Q ÷ V

    667 mm²

  2. 2

    Diameter

    √(4A/π)

    29.1 mm

  3. 3

    Standard size

    next size up

    32 mm

Worked example

  1. 160 lpm = 0.001 m³/s at 1.5 m/s → area 0.000667 m².
  2. 2Diameter = √(4 × 0.000667 ÷ π) = 0.0291 m = 29 mm.
  3. 3The next standard size is 32 mm (1 inch) PVC.

Tips

  • Use 25 mm for a single tap line, 32–40 mm for a house main, 50 mm+ for pumps above 2 HP.
  • Every 90° elbow adds roughly 1 m of equivalent pipe length.

Frequently asked questions

What size pipe for a 1 HP pump?

Usually 32 mm (1 inch) suction and delivery; go to 40 mm on runs longer than 30 m.

Is a bigger pipe always better?

Hydraulically yes, but cost rises fast. Sizing for 1.5 m/s is the sensible balance.

Why does flow drop at the top floor?

Friction in an undersized pipe plus the extra lift. Increasing the main pipe size usually fixes it.